5m White LED Strip Light/Tape Light - Dual Row - 12V/24V - IP20 - 520 Lumens/ft
This flexible dual-row LED strip light operates on 24 VDC and can be used in longer runs than 12V strips. It emits up to 520 lumens of cool, natural, or warm white illumination per foot. The 16.4' LED tape light can be easily cut into separate 6-LED segments and installed with its Peel-and-stick 3M™ adhesive backing enables fast, easy mounting. Backed by a lifetime warranty.
Features:
- Dependable, industry-standard 3528 SMD LEDs
- 80+ CRI rating ensures vibrant, natural-looking color tones
- 73 LEDs/ft
- 12VDC /24 VDC input
- Maximum run of 10m
- Strip width measures 14mm
- Lifetime exceeds 50000 hours
- CE certified and UL listed
- Lifetime warranty
Available Colors CCTs
Installation:
- Easy installation with double adhesive tape.
- Don't press the LED lights heavily when fixing the strip.
- Fix the one end of strip first and press the edge smoothly to another end.
- The angel between the surface and the strip being pulled should not exceed 20 degrees.
- Minimum bending diameter is 6 cm(2.36in).
Warranties & Certifications
Should you select 12 Volt (12v) or 24 Volt (24v)?
Depends on your application. The main difference between the two is the fact that the 24v strips can be ran for longer distances than the 12v strips can due to Voltage Drop. Voltage drop is the gradual decrease in voltage along a circuit. If your project requires a very long run of LEDs, we would recommend the 24v strips. However, there are also many projects that 12v is required (automotive or marine applications). Please feel free to live chat with us, or email us with questions.
Before noticing any unwanted color variations or dimming at the end of your run of lights, it is recommended that you run no more than 32' in series when using 12v or 48' in series when using 24v.
Application & Use
SmartBrightLEDs White Series LED strip lights are installed in a wide variety of applications including:
TV backlighting, Linear lighting, Cove lighting, Display / jewelry case lighting, Bar and restaurant accent lighting, Above cabinet lighting, Under counter lighting, Hotel lobbies, Cove lighting
TECHNICAL DETAILS
Brightnes | 520 lm/ft (1706 lm/m) |
CRI | 80+ |
Connection Type | Pigtail |
IP Rating | Non-Weatherproof |
LED Beam Angle | 120° |
LED Density | 73 LEDs/ft. |
LED Type | 3528 SMD |
Strip Width | 14mm (0.551in) |
LED Quantity | 1200 LEDs |
LED per Segment | 12 |
Rated Lifespan | 50,000 hours |
Length | 16.4ft (5m) |
Dimmable | Yes (requires Controller) |
Efficacy | 90 lm/w |
Wire Length | 508mm (20in) |
Minimum Cut Length | 50mm (2in) |
Wattage | 5.8 W/ft (19 W/m) |
Wattage Total | 95 Watts |
Operating Temperature | -20~+45 °C (-4~+113 °F) |
Standards And Certifications | CE, RoHS Compliant, UL Listed |
**All specifications are subject to change without notice.
Incorrect Use:
Packaing Diagram
Use of environmental conditions
1). LED strips installation must be operated by professionals.
2). For avoiding LED get vulcanized, LED strip should be installed in the environment where does not has oil and corrosive substances. Such as these substances which contain Sulphur、Bromine、Iodine and Chlorine. Some other chemical elements which will cause Aromatic hydrocarbons releasing(such as: methylbenzene、xylene、methyl acetoacetate Ethyl acetate etc.).The environment in which includes strong acid and strong base.
3). For cutting LED strip operation, it is necessary to use the standard accessories provided by smartbrightLEDs (e.g. DC wire, end-cap, front-cap, adhesive, etc.), and according to the correct cutting and connecting method for the installation.
4). LED strip cannot be installed in some areas where water hazard might be formed, such as the surface of pits and ditches. And similar places in which rain and water may be accumulated easily.
5). Please do not strongly pull、crash the LED strips during installation process. And avoid squeezing and scratching LED strips with sharp objects.
6). During the warranty period, only defective products are acceptable to be replaced by the factory. Factory is not responsible for other expenses because of replacement,such as transportation fee, installation fee, etc.
Cautions 1. In order to guarantee the LED life and the use environment, cannot make any force when the product lighting use to pull the power cables, forbids to collide, in order to avoid damages LED. 2. For better lighting effect of the product, each 5 meters strip must connect the main power source. 3. Must guarantee that each power source (GND) must be connected. 4. Should not be curving in the diameter 60mm following radian, please do not rebate, in order to avoid damage lamp bead or break. 5. Please follow the user manual for installation. 6. Please note the careful operation, in the power source connection's situation, will touch the alternating current supply end possibly to cause your safety. 7. In the actual application, the power source should retain 20% remainders, guaranteed that the sufficiency the voltage lightens LED. 8. Installs as far as possible the product in the appropriate environment. 9. Pays attention to the power cable in the installment process positive and negative extremely, please do not wrong, power source and product voltage to be whether correct, in order to avoid creates the product the damage. |
** If you do not follow the above "Cautions" to operate and result in damaging the product, the factory will not accept maintenance and return.